SFR · Available

Symmetric Fixture Removal

Remove the effects of a symmetric test fixture from your VNA measurements with IEEE P370 2xThru de-embedding, applied live on the analyzer.

Symmetric Fixture Removal main window with the step bar, ready checks and VNA status panel
Main window after characterizing a fixture. Example data.

Key features

  • Guided workflow from project setup and calibration check to fixture removal, with a step bar that shows what to do next.
  • Measures a fresh 2xThru, splits it into left and right fixture halves with IEEE P370 (NZC) and loads them into the analyzer's de-embedding, so the VNA shows the DUT alone, live.
  • Ready checks before you apply — calibration state, sweep coverage, sweep points and port impedance — with one-click fixes where possible.
  • Jumper correction for fixtures whose halves are joined by a wire, U-wire or PCB trace bridge during the 2xThru, described by a model or a Touchstone file.
  • Time-domain (TDR) view with an impedance profile and an automatic fixture symmetry check.
  • Cascade check that confirms the extracted halves rebuild the measured 2xThru.
  • Build a model from a saved 2xThru Touchstone file without a new sweep.
  • Uses the analyzer's own system impedance, so 75 Ω and 50 Ω set-ups are handled the same way.

The problem

A test fixture — coax-to-board launches, pads and traces — sits between your calibrated cable ends and the device under test. Its loss, delay and mismatch end up in every measurement. Calibrating at the DUT pads is rarely practical, so the fixture has to be removed mathematically.

How it works

  1. Calibrate a full 2-port calibration at the cable ends that mate with the fixture, on the VNA as usual.
  2. Characterize the 2xThru: the left and right fixture halves joined where the DUT will sit. The plugin takes a fresh sweep and splits it into a left and a right half with IEEE P370.
  3. Check the result: ready checks, the cascade check and the time-domain symmetry view tell you whether the model is sound before you rely on it.
  4. Enable fixture removal: the halves are loaded into the analyzer’s de-embedding, and the VNA shows the DUT alone, live, with the same cables, calibration and sweep.

Good practice

  • Sweep about 10 % beyond the highest frequency you need; the ready checks confirm this.
  • Use the same sweep points and IF bandwidth for calibration, 2xThru and DUT.
  • Verify with fixture removal on: the 2xThru should then look like an ideal through. A short line of known impedance is the best final check.

Accuracy depends on your fixture, connectors and calibration. Any figures in the user manual come from simulations and are examples, not guaranteed values.

Specifications and requirements

MethodIEEE P370 2xThru de-embedding (NZC), symmetric fixtures
Tested onCopper Mountain 2-port VNAs
Runs asS2VNA plugin, started from the analyzer software's plugin menu
Operating systemWindows 10 or Windows 11
CalibrationFull 2-port calibration done on the VNA; the plugin never changes it
LicensePerpetual, bound to a PC, a VNA serial number or both; covers all 1.x updates
Trial1-week trial license with all functions on one PC

Frequently asked questions

Does Symmetric Fixture Removal change my VNA calibration?

No. You calibrate on the VNA as usual. The plugin measures the 2xThru, writes the two fixture-half files and turns the analyzer's built-in de-embedding on or off. It never changes your calibration.

Does my fixture have to be symmetric?

Yes. The IEEE P370 2xThru method assumes the left and right fixture halves are mirror images. The time-domain view includes a symmetry check so you can confirm this before you measure.

Which analyzers does it work with?

It is tested on Copper Mountain 2-port VNAs, with Windows 10 or 11 on the PC. If you plan to use a different analyzer, ask us before you buy.

How does the free trial work?

Request a trial and we send a 1-week trial license with all functions for one PC. The plugin's activation screen gives you a short request text with your machine ID to include in the email.

How do I buy a license?

Request a quote. We reply with a quote. Payment by secure PayPal invoice. Your perpetual license file follows by email and covers every 1.x update.

Try Symmetric Fixture Removal on your own bench

Request a free trial license, or a quote for your team.